Tags

Tags give the ability to mark specific points in history as being important
  • v3.6.0

    5890709c · redo requirements ·
    ## v3.6.0
    - Major refactory of all libraries. New beamline_utils.py
    
    - Rewrite PyNexus with h5py.
    
    - Remove example.zip from git.
    
    - Adapt tests to pass on Windows and macOS.
    
    TO BE DONE : extraction of several cells should not crash if 2D is not inside
    
    ## v3.5.1
    - Mythen : add module for Mythen extraction and GIXD.
    
    - Rewriting the docs.
    
    - Adding pytest.
    
    ## v3.5.0
    - GIXS : do not use qxy but qy. Users should get qxy (and deal with the missing wedge) in other analysis software.
    
    - Calib XRR liquid : new procedure with first zs then gamma.
    
    - Add sensors : parsing of sensors to add is more tolerant on sep.
  • v3.4.1

    8adc79cc · Quick fix ·
    ## v3.4.1
    - XRR liquid: Revise the tracking of the beam. Fit only on the last points, expose the parameter controlling the tolerance between the prediction and the maximum. Change default value of m4pitch0 to 0. Print ROI information.
  • v3.4.0

    f7cd6199 · Quick fix on XRR liquid ·
    ## v3.4.0
    - Form: Add M4 Super Mirror Track.
    
    - Add the possibility to print the mean/first/last values of selected sensors in GIXS, GIXD, area_detector, XRF, Data 1D, XRR.
    
    - GIXS, area_detector: returns now `images`, which contains all the images from the scan is extract_each is True, else None.
    
    - XRR_liquid: correct bug if the selected scan is not a XRR.
    
    - XRR: the background by default is now left/right instead of up/down.
  • v3.3.0

    9ea6bd6a · add example ·
    ## v3.3.0
    - Paths: change the 1st cell to get easier compatibility between macos and windows.
    
    - XRR Solid: the incident angle is computed using alphax now, instead of gamma before.
    
    - UFXC: add new dead pixels.
    
    - GIXD/GIXS: add the possibility to force an offset on gamma or delta (GIXS only).
    
    - Printing the attenuators is True by default.
  • v3.2.5

    ## v3.2.5
    - XRR Solid: Now XRR.dat has the same format on liquid and solid.
    
    - Enlarge the scan selection window.
  • v3.2.4

    ## v3.2.4
    - GIXD: Fix bug when a 2D detector is present but images are empty.
    
    - Set is_print_abs to True by default.
  • v3.2.3

    92e21237 · Redo sphinx doc ·
    ## v3.2.3
    - Add the possibility to print the mean values of selected sensors in GIXS, GIXD, area_detector, XRF.
    
    - Add two levels of remarks in insert text.
    
    - Redo the sphinx documentation.
  • v3.2.2

    cf2ed1e3 · Example for 3.2.2 ·
    ## v3.2.2
    - Flyscan update: add the possibility to read nexus files generated by the flyscan. Works for plot 1D, plot images, and plot GIXD.
    
    - Update XRR: add a nanmean instead of a mean of the ionchamber (it can return a nan if the integration time is too long). Also, do not save all the dat files (only the first one) to save time.
  • v3.2.1

    ## v3.2.1
    - Integration of fast attenuators.
  • v3.2.0

    ## v3.2.0
    - Solve problem of nan in energy calib.
    
    - Add more digits in erf/gaussian fit display.
    
    - Message at start when a folder is missing is clearer.
    
    - Change nb of characters to split in two lines in Title and Remarks.
    
    - Replace typo sprectogram.pdf with spectrogram.
    
    - Major update on XRR on liquids : measure only one gain on the ionchamber per point.
    
    - Remove howto from docs.
  • v3.1.2

    7fb5a850 · remove dead link ·
    ## v3.1.2
    
    - Update LICENCE, CONTRIBUTORS, docs.
    
    - GIXS/area_detector: possibility to control the color scale (min, max).
    
    - Manual: it was made more explicit that no correction related to the geometry of the experiment (flat detector, missing wedge, ...) are applied to GIXS/GIXD images. Users should use other softwares/notebook to process the data.
  • v3.1.1

    Update to v3.1.1 :
    - GIXS/area_detector: Set the ROI to -1 to get the whole detector.
    
    - data_1d: Add the possibility to plot two curves with the same x-axis in 1D plot.
  • v3.1.0

    Update to v3.1.0:
    
    - GIXS/area_detector: integrate spectra only on an ROI defined by the user and shown on the image with a red rectangle. But it is still the full profiles that are saved as dat files.
    
    - insert_text: add a category "Remark", which appears in large bold letters.
    
    - fill_form: bug correction, the title was not in Large anymore.
    
    - GIXD: add possibility to do GIXD with UFXC. ROI_soller is now defined by user.
  • v2.12

    Update to v2.12
  • v2.11.1

    ef73f3e9 · Release v2.11.1 ·
    Update to v2.11.1
  • v2.10.4

    bc54aae3 · Update manual XRF ·
    Update to v2.10.4
  • v2.10.3

    9fd1a4cc · Add example.zip ·
    Update to v2.10.3
  • v2.10.2

    b023d035 · Manual for v2.10.2 ·
    Update to v2.10.2